• Ceramic Fiber Insulation Blanket 128K
  • Ceramic Fiber Insulation Blanket 128K
  • Ceramic Fiber Insulation Blanket 128K
  • Ceramic Fiber Insulation Blanket 128K
  • Ceramic Fiber Insulation Blanket 128K
  • Ceramic Fiber Insulation Blanket 128K

Ceramic Fiber Insulation Blanket 128K

Usage: High Temperature Insulating Material
Temprature Classification: 1400℃, 1260℃
Chemical Composition:: Al2O3.SiO2
Shape: Ceramic Fiber Blanket
Manufacturing Technique: Spray Silk Rug
Kind: Ordinary Ceramic Fiber
Customization:
Gold Member Since 2009

Suppliers with verified business licenses

Beijing, China
to see all verified strength labels (14)

Basic Info.

Model NO.
STD, HP, HA, HZ
Temperature Grade
1260c-1430c-1600c
Standard Size
7200X610X25mm ; 3600 X610 X 50mm
Density
64-160 Kg/M3
Delivery Time
Usually for Regular Order Within 14 Days
Transport Package
First by PP Bags, Then by Cartons
Specification
ISO9001
Trademark
NR
Origin
China
HS Code
68061010
Production Capacity
40000 Tons/Year

Product Description

High Temperature Thermal Ceramic Fiber Blanket
Spun ceramic fiber blanket are lightweight and thermally efficient, resulting in a material that possesses the advantages of low heat storage and complete resistance to thermal shock. Used in a variety of heat processing applications, the ceramic fiber blanket is produced from high strength spun ceramic fibers and is needled to provide exceptional handling strength. The ceramic fiber blanket is completely inorganic and is available in a variety of densities, thicknesses, widths and temperature ratings:

Typical Grades and Dimensions
Commercial grade: service temperature 1800°F
High-Purity grade: service temperature 2300 °F
Zirconia grade: service temperature 2600 °F
Standard Densities: 6, 8 Ibs./cu. ft. (96, 128 kg/m3)
Standard Thicknesses: 1/2", 1", 1-1/2",2"
Standard Widths: 24" and 48"
Standard Packaging: Cartons or bags

Ceramic Fiber Blanket - Typical Applications
Furnace repair Furnace, kiln, reformer and boiler linings   Furnace door linings and seals
Reusable insulation for steam and gas turbines   High-temperature kiln and furnace insulation
Primary reformer heater insulation   High temperature gasketing   Expansion joint seals
Glass furnace crown insulation     Field steam generator lining   Nuclear insulation applications
Thermal reactor insulation   Flexible high temperature pipe insulation   Investment casting mold wrapping
Removable casting mold wrapping  Removable insulating blankets for stress relieving welds
Pressure and cryogenic vessel fire protection   Soaking pit seals   High temperature filtration
Incineration equipment and stack linings
Specifications : 

Grade
1260Blanket 1430Blanket 1500Blanket 1600Blanket
ClassificationTemperature ° C 1260 1430 1500 1600
Recommend UsingTemperature ° C 1100 1250 1300 1580
MeltingPoint ° C 1760 1760 1760 1760
Fiber Diameter μm 3.5 3.5 3.5 3.1
Fiber Length mm 250 250 150 100
Shot Content(>212 μm) % 18 18 15 0.11

Chemical Composition
A l  2  O  3 % 47.1 35 40 72
Si O  2 % 52.3 49.7 57.8 28
Zr O  2 % - 15 - -
Cr  2  O  3 % - - 2.0 -
Bulk Density k g / m 3 96;  128;  160; 128
Thermal Conductivity
W/(m. K)
Density in 128kg/m 3
400 ° C 0.10      
600 ° C 0.15 0.14 0.13 0.09
800 ° C 0.24 0.23 0.21 0.13
1000 ° C   0.29 0.27 0.19

Available Size

mm
Length x Width x Thickness
7200x610x6 ;  7200x610x12.5;
7200x610x20;  7200x610x25;
3600x610x38;  3600x610x50;

Packing : by carton box or pp woven bags

Ceramic Fiber Insulation Blanket 128KCeramic Fiber Insulation Blanket 128K


Delivery Time  :  within 15 days.

Typical Dimensions :
Classification Temperature/ Theoretical Density Ceramic Fiber Blanket 
2300 °F (1260 °C)
Ceramic Fiber Blanket 
2600 °F (1427 °C)
8 lb/ft³ (128 kg/m³) 1 x 24 x 300 in
1 x 48 x 300 in
1.5x 48 x 200 in
2 x 24 x 150 in
2 x 48 x 150 in
0.5 x 24 x 600 in
0.25 x 48 x 1200 in
1 x 24 x 300 in
1 x 48 x 300 in
2 x 24 x 150 in
6 lb/ft³ (96 kg/m³) 1 x 24 x 300 in
2 x 24 x 150 in
 
Thermal Conductivity (W/mK)
(128 kg/m³ 8 lb/ft³)
(Mean Temperature: 500 °C)
<= 0.153 <= 0.153
Tensile Strength MPa
(25 mm or 1 inch thick)
0.06 0.06

Ceramic Fiber Blanket Datasheet:

  • View / download Bio-Soluble Blanket Datasheet
  • View / download 2300F, 2600F Ceramic Fiber Blanket Datasheet

Ceramic Fiber Blanket Data Sheet Chart:

Description

STD RCF Blanket HP RCF Blanket HZ RCF Blanket

Chemical Composition (%) 

Al2O3

≥44 ≥45 ≥34

SiO2

≥52 ≥54 ≥50

Fe2O3+TiO2

≤1 ≤0.5 ≤0.5

ZrO2

- - ≥15

K2O+Na2O

≤1 ≤0.2 ≤0.2

Physical Properties 

Density (kg/m³)

96 128 96 128 160 96 128 160

Classification Temperature (°C)

1260 1260 1430

Fiber Diameter (um)

3.5 3.5 3.5

Shot Content (%)

≤15 ≤15 ≤12

Linear Shrinkage after heating (%)  

1000°C*24h≤2.5 1100°C*24h≤2.5 1350°C*24h≤3.5

Thermal Conductivity (W/mK) 

400°C

0.090 0.095 0.124 0.114 0.101 0.138 0.122 0.118   

500°C 

0.119 0.123 0.145 0.135 0.120 0.179 0.153 0.149   

600°C

0.152 0.158 0.202 0.191 0.175 0.233 0.184 0.172   

Tensile Strength (MPa) 

0.040 0.050 0.050 0.060 0.075 0.050 0.060  

 